Parker authorised distributor

32 questions

Topic 01

General

Topic page
What does DHE Endüstriyel do?

It provides site surveys, product selection, installation, maintenance and spare parts for compressed air and gas systems. It is the Türkiye distributor of the manufacturers in its portfolio.

Which brands do you work with?

Parker domnick hunter, CompAir, Boge, Sauer Compressors, Belliss & Morcom, BSL, CS Instruments and Hanwha. Each brand’s page lists its series and documents.

Who provides the service?

DHE’s own technical service team. The team that commissions the system also handles maintenance, breakdowns and spare parts.

What information do you need for a quote?

Type of need, flow or capacity, pressure, required purity, daily operating hours and industry. If you don’t know a value, we determine it together during the site survey.

Which facilities is on-site nitrogen generation suitable for?

Facilities with regular nitrogen consumption. Suitability depends on consumption, required purity and current supply cost; we carry out the preliminary assessment together.

Topic 02

Nitrogen generators

Topic page
Where is nitrogen used?

Nitrogen provides a clean, dry and inert atmosphere wherever oxygen is unwanted in environments and processes: laser cutting, food packaging, chemicals, electronics assembly, pharmaceuticals and heat treatment are some of them.

What should be considered when choosing a nitrogen generator?

The first step is a careful analysis of the user’s process information, consumption and consumption trend. Since each application needs different nitrogen purities and pressures, the aim is both to meet the requirement and to offer the most economical solution.

PSA or membrane?

The choice depends largely on the purity required. PSA generators can reduce residual oxygen to 5 ppm; membrane modules produce 95% to 99.5% nitrogen (0.5–5% residual oxygen). In this range both technologies can be used; the decision depends on flow, compressed air consumption and installation.

Why is purity given as “residual oxygen”?

Gas companies usually state purity as nitrogen content (e.g. 99.9%); with generators, the value measured and controlled is residual oxygen (0.1% in the same example). Because of the argon in air, nitrogen content is never exactly 100%, so residual oxygen is the more accurate measure.

Under which conditions are flow rates given?

Parker states flow rates at 20 °C, 1013 mbar(a) and 0% relative humidity. If your requirement is defined in Nm³/h (0 °C), it must be converted: for example, 20 Nm³/h corresponds to about 21.5 m³/h.

How much can on-site generation save?

According to Parker, savings of up to 90% are possible compared with cylinder or liquid supply; the typical payback period is 12–24 months. The actual figure for you depends on your consumption and current supply cost.

How does purity affect flow?

The same generator model can produce nitrogen at different purities, but the flow depends on purity: the less oxygen required, the lower the outlet flow. Defining the purity you need correctly lets you choose a smaller and therefore more economical system. With NITROSource Plus, residual oxygen can be set between 5 ppm and 3%.

What is the payback period?

According to Parker, the typical payback period is 12–24 months; savings of up to 90% are possible compared with cylinder or liquid supply. The actual figure for you depends on your consumption and current supply cost.

What compressed air quality does the generator need?

Inlet air must be at least ISO 8573-1:2010 Class 2.4.1; a dryer and filters are installed upstream of the generator for this. During the site survey we measure your existing line and add pre-treatment if needed.

What if our nitrogen demand grows?

You don’t need to replace the generator with a bigger one; a parallel module is added to the system. Added modules provide redundancy, so there is no gas interruption during maintenance.

Who carries out maintenance?

DHE’s own technical service team. It handles periodic maintenance, analyser checks, filter element replacement and breakdown response; we keep frequently replaced parts in stock.

Topic 03

Food & beverage

Topic page
What class should compressed air in contact with the product be?

According to ISO 8573-1 and HACCP, compressed air in contact with the product must be brought to at least Class 1.2.1. Coalescing filters retain solid particles and oil/water aerosols down to 0.01 micron, activated carbon filters reduce the oil content to 0.003 mg/m³, and 0.2 micron membrane filters finally provide sterilisation.

Which gases are used in MAP?

MAP generally uses mixtures of pure nitrogen (N₂), carbon dioxide (CO₂), oxygen (O₂) and carbon monoxide (CO). For products such as sucuk, pastırma, cheese, fish and filo pastry, mixtures of 50–80% nitrogen and 50–20% carbon dioxide are common; the ratio depends on the product.

Can the gas mixture be prepared on site instead of buying cylinders?

Yes. Nitrogen produced by a PSA nitrogen generator is mixed in the required ratio with carbon dioxide fed to the gas mixer from a separate source. Cylinders are often preferred because they need no initial investment, but for companies using one cylinder a day or more, on-site generation with a nitrogen generator and gas mixer is far more advantageous.

Why is CO₂ for beverages purified?

Depending on how it is sourced (by-product, geothermal source, flue gas treatment), carbon dioxide can carry impurities that spoil the colour, odour and taste of the drink. Organisations such as ISBT, CGA and EIGA have set standards for CO₂ used in beverages; the PCO₂ purification system keeps the gas within these quality guidelines.

Does compressed air need to be sampled?

Quality management systems such as GMP, BRC, FDA, HACCP and ISO 22000 require compressed air to be sampled at regular intervals to control production quality. With a compressed air sampling kit, samples can be taken into Petri dishes at any point in the plant; the kit can be used on any line up to 10.3 bar(g).

Why is nitrogen blanketing used in tanks?

If atmospheric air enters the space left as a tank empties, its oxygen promotes oxidation and microbiological growth in the food. Feeding nitrogen into the tank headspace under pressure control keeps the oxygen level below critical limits.

Topic 04

Parker domnick hunter

Topic page
What is DHE’s relationship with Parker domnick hunter?

DHE Endüstriyel started out in 2002, as TFM Mühendislik, as the distributor of domnick hunter, and is today Parker’s distributor in Türkiye in this field.

Which products are in the Parker domnick hunter portfolio?

Coalescing line filters and activated carbon filters used in compressed air systems, refrigerated and adsorption (desiccant) dryers, water separators, and electronic and manual condensate drains; as well as nitrogen generators, chillers and breathing air systems.

Are Hiross and Zander products also available?

Yes. Parker acquired the domnick hunter, Hiross and Zander brands in 2005; Hiross and Zander compressed air treatment equipment has been part of DHE ever since.

Where is after-sales service provided?

Sales and after-sales service for every product we sell is provided across Türkiye and abroad. Installation or supervision, and periodic, preventive and predictive maintenance are carried out by our service team.

Are spare parts kept in stock?

To avoid process interruptions, we keep spare parts that may be needed urgently in stock. You can reach our service team 24/7 on the mobile numbers provided during service.

Topic 05

Service & spare parts

Topic page
Which products do you service, and where?

Sales and after-sales service for every product we sell is provided across Türkiye and abroad.

Can I reach the service team outside working hours?

You can reach our service team 24/7, whenever you need, via the mobile numbers given to you during service.

Are spare parts in stock?

To avoid process interruptions and meet your needs as quickly as possible, we keep spare parts that may be needed urgently in stock.

What does an air quality measurement cover?

Oil vapour, water vapour (humidity), CO and CO₂ and dew point temperature are measured, and particles are counted. Results are analysed and reported according to ISO 8573-1.

Why should air quality be measured regularly?

If you do not measure and analyse your compressed air system regularly, you can only tell whether the equipment that removes contaminants is adequate once you run into problems. Pneumatic tools corroded by moisture and products spoiled by oil are just two of these problems.

Contact

Let’s clarify your needs together.

Weekdays 08:30 – 18:00

Çerezler