Parker authorised distributor
Parker domnick hunterGas generators

Nitrogen Generators

By separating the oxygen molecules from the compressed air your compressor supplies, you can produce nitrogen at the purity you need and put an end to costly cylinder or liquid nitrogen supply.

PSA and membrane · 4 series

(0216) 549 26 80WhatsApp

Nitrogen outlet flow
0.3 – 201m³/h
At 7 bar(g) inlet, depending on model and purity
Purity · residual oxygen
5 ppm – 5%
PSA down to 5 ppm, membrane down to 0.5%
Inlet pressure
4 – 13bar(g)
Varies by series
Technology
4series
PSA and membrane
Overview

Air is 78% nitrogen; stop paying for gas.

Nitrogen is used to provide a clean, dry and inert atmosphere wherever oxygen is unwanted in environments and processes. With a nitrogen generator you separate the oxygen molecules in the compressed air from your compressor, produce nitrogen at any purity between 5 ppm and 95%, and put an end to costly cylinder or liquid nitrogen supply.

Benefits of a nitrogen generator

  • A nitrogen generator can be fed from a standard air supply; thanks to on-demand delivery and economy mode, nitrogen production, flow and purity can be controlled.
  • The nitrogen produced is not wasted as with conventional sources, and the evaporation losses of liquid nitrogen disappear, bringing extra savings.
  • Running 24/7 without interruption, it prevents downtime and production losses caused by running out of nitrogen.
  • On-site generation removes the burdens of external supply such as refills, ordering, tank rental, delivery charges and future price increases by the supplier.
PSA and membrane

Two technologies, one family.

Parker domnick hunter nitrogen generators separate nitrogen from compressed air in two different ways.

NITROSource Plus PSA nitrogen generatorsPSA

PSA nitrogen generators

Pressure Swing Adsorption (PSA) technology uses CMS (carbon molecular sieve) columns to separate compressed air. The vessels of PSA generators are filled with CMS granules, a special adsorbent material.

Residual oxygen
5 ppm – 5%
Nitrogen flow · 7 bar(g)
0.8 – 197.3 m³/h
Series
NITROSource Plus · Compact
PSA series
Parker membrane nitrogen modulesMembrane

Membrane nitrogen generators

Membrane technology consists of bundles of porous membrane fibres placed in a tube. Oxygen and other gases in the compressed air diffuse out through the membrane walls and are vented, while the nitrogen remaining inside the membrane is delivered to the system.

Residual oxygen
0.5% – 5%
Nitrogen flow · 7 bar(g)
0.3 – 201 m³/h
Series
HiFluxx · SmartFluxx
Membrane series

Which one?

The choice depends largely on the purity required: very high purity (residual oxygen at ppm level) calls for PSA, while the 95–99.5% nitrogen range can be met by both technologies. Let us determine the right technology together based on your consumption and purity needs.

How it works · PSA

Two column banks, uninterrupted nitrogen.

In PSA nitrogen generators the vessels are filled with CMS (carbon molecular sieve) granules, a special adsorbent. Select the steps to follow the cycle.

A B O₂ Compressed air Dryer + filter Vent O₂ analyser Buffer tank Nitrogen
Compressed airNitrogenRetained and vented oxygen
Selection table

Choose a model by purity and flow.

The same nitrogen generator model can produce nitrogen at different purities, but the flow depends on purity: the higher the purity, the lower the outlet flow. Defining the purity you actually need lets you choose a smaller, more economical system.

Technology

37 models · 1% residual oxygen

Nitrogen generator models, nitrogen outlet flow at the selected purity
Model Series Technology Nitrogen flow · m³/h 1% Status Page
ST304 HiFluxx Membrane 0.3 View
ST504 HiFluxx Membrane 0.4 View
ST604 HiFluxx Membrane 0.7 View
SA604 SmartFluxx Membrane 0.7 View
DT304 HiFluxx Membrane 0.9 View
TT304 HiFluxx Membrane 1.4 View
ST606 HiFluxx Membrane 1.4 View
DT604 HiFluxx Membrane 2.1 View
ST608 HiFluxx Membrane 2.5 View
TT604 HiFluxx Membrane 2.8 View

Flow rates are for 7 bar(g) inlet pressure; m³ refers to 20 °C, 1013 mbar(a) and 0% relative humidity (NITROSource Compact: 25 °C). Membrane values are the lowest outlet flow of the module. Parallel units are suggested only for NITROSource Plus, which runs multi-banked. This table is a preliminary selection; the final choice is made after reviewing your consumption profile and air line.

Frequently asked questions

About nitrogen generators.

Where is nitrogen used?

Nitrogen provides a clean, dry and inert atmosphere wherever oxygen is unwanted in environments and processes: laser cutting, food packaging, chemicals, electronics assembly, pharmaceuticals and heat treatment are some of them.

What should be considered when choosing a nitrogen generator?

The first step is a careful analysis of the user’s process information, consumption and consumption trend. Since each application needs different nitrogen purities and pressures, the aim is both to meet the requirement and to offer the most economical solution.

PSA or membrane?

The choice depends largely on the purity required. PSA generators can reduce residual oxygen to 5 ppm; membrane modules produce 95% to 99.5% nitrogen (0.5–5% residual oxygen). In this range both technologies can be used; the decision depends on flow, compressed air consumption and installation.

Why is purity given as “residual oxygen”?

Gas companies usually state purity as nitrogen content (e.g. 99.9%); with generators, the value measured and controlled is residual oxygen (0.1% in the same example). Because of the argon in air, nitrogen content is never exactly 100%, so residual oxygen is the more accurate measure.

Under which conditions are flow rates given?

Parker states flow rates at 20 °C, 1013 mbar(a) and 0% relative humidity. If your requirement is defined in Nm³/h (0 °C), it must be converted: for example, 20 Nm³/h corresponds to about 21.5 m³/h.

How much can on-site generation save?

According to Parker, savings of up to 90% are possible compared with cylinder or liquid supply; the typical payback period is 12–24 months. The actual figure for you depends on your consumption and current supply cost.

Contact

Let’s choose the right nitrogen system together.

Weekdays 08:30 – 18:00

Çerezler

Zorunlu çerezler sitenin çalışması için gereklidir. Analiz ve pazarlama çerezlerini yalnız izninizle kullanırız. Çerez Politikası